Filters
More in this category
Contactors
part#
description
manufacturer
AF2612-2SD
ABB Control - AF2612-2SD
ABB Control
Quick Quote
AF091F2-2D11D
ABB Control - AF091F2-2D11D
ABB Control
Quick Quote
LP1K1201JD
Schneider Electric LP1K1201JD is a magnetic contactor within the K sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 12A at 440Vac under AC-3 conditions. The contactor's net width is 45 mm and it offers a degree of protection rated at IP20. The control voltage (DC) specifications are 9.6-13.8Vdc, with a nominal 12Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). It operates at a rated operating voltage (Ue) of up to 690 V and includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, being 3kW at 220-230Vac, 5.5kW at 380-415Vac and 440Vac, and 4kW at 500Vac and 660-690Vac, all under AC-3 conditions. Its mechanical durability is rated for 10,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
CWM9-10-30X47
WEG CWM9-10-30X47 - CONTACTOR CWM9-10-30X47, Contactors (CWM)
WEG
Quick Quote
CWC012-00-22R06
WEG CWC012-00-22R06 - MINICONTACTOR CWC012-00-22R06, Miniature Contactors (CWC)
WEG
Quick Quote

BFD6500A57560
BFD6500A57560 Lovato - Three-pole contactor, 35A/1000V DC1, AC coil, 575VAC 60Hz
Lovato Electric
Quick Quote

CA7-43-01-208
Contactor, 3 Pole, Non-Reversing, 85A, NC Auxiliary Contact, 208 VAC Coil
Sprecher + Schuh
Quick Quote
LC1D40AYC7
Schneider Electric LC1D40AYC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor supports a rated current of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 528-726Vac (660Vac nominal; 50Hz; 0.8...1.1 x Uc) to 561-726Vac (660Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 11kW (220-230Vac; AC-3) to 30kW (660-690Vac; AC-3). The rated power (HP) ranges from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). This contactor is designed for mechanical durability of 6 000 000 operations and electrical durability of 1 500 000 operations with load, with a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote

11G222C48
11G222C48 Lovato - Mechanical latch. Screw terminals for BF00, BF09-BF38
Lovato Electric
Quick Quote

AF38B-30-00RT-14
AF38B-30-00RT-14 ABB Control - AF38B 250-500V50/60HZ-DC
ABB Control
Quick Quote

BF65T4A048
BF65T4A048 Lovato - Four-pole contactor, IEC operating current Ith (AC1) = 100A, AC coil 50/60Hz, 48VAC
Lovato Electric
Quick Quote
AF261N1-GP
ABB Control - AF261N1-GP
ABB Control
Quick Quote
LC1D115B5
Schneider Electric LC1D115B5 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 200A for AC-1 and 115A for 440Vac in AC-3. This contactor is suitable for DIN rail mounting and has a net width of 120 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 20.4-26.4Vac (24Vac nominal; 50Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 1000 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 30kW at 220-230Vac to 80kW at 660-690Vac in AC-3, with specific ratings for different voltages. The rated power in horsepower (HP) varies from 30HP at 200-208Vac to 100HP at 575-600Vac for 3-phase, 50Hz/60Hz, UL/CSA. The mechanical durability of the LC1D115B5 is rated at 8 million operations at no load, and its electrical durability is rated at 950,000 operations with load. The rated voltage for phase-to-phase is 1000 V.
Schneider Electric
Quick Quote

11BGF09T4D048
11BGF09T4D048 Lovato - Four-pole contactor, DC coil, 48VDC, Faston terminals
Lovato Electric
Quick Quote
LC1DT206FE7
Schneider Electric LC1DT206FE7 is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and equipped with 4 poles (4NO). This contactor has a rated current of 20A (AC-1) and is suitable for DIN rail mounting. It features a net width of 45 mm and offers a degree of protection rated at IP20. The control voltage for AC is specified at 92-126Vac (115Vac nominal; 50Hz; 0.8...1.1 x Uc) and 98-126Vac (115Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and the mechanical durability at no load is rated for 15,000,000 operations. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Schneider Electric
Quick Quote

11B630L00220110
11B630L00220110 Lovato - Three-pole contactor, IEC operating current Ie (AC3) = 630A, AC/DC coil, already fitted with mechanical latch (G495), 220...240VAC/DC, mechanical latch 110...125VAC
Lovato Electric
Quick Quote
J7TKN-A-E6
Omron J7TKN-A-E6 - Contactor
Omron
Quick Quote
AF261B1-GM1J
AF26,NR,3PH,CB,N1,480/24V
ABB Control
Quick Quote

CA9-2050-EI-11-120W
Sprecher + Schuh CA9-2050-EI-11-120W - CA9 Contactor w/PLC Inputs, A, 100-250V 50-60 Hz AC/DC, 1NO1NC
Sprecher + Schuh
Quick Quote
GJL1311501R8000
ABB GJL1311501R8000 is a magnetic mini contactor from the B7 contactors sub-range, designed with screw-clamp connections and featuring 4 poles (2NO+2NC). It has a rated current of 20A at 380-400Vac (40°C; AC-1), 16A at 380-400Vac (55°C; AC-1), 6A at 690Vac (40°C; AC-1), 6A at 690Vac (55°C; AC-1), 4A at 24-120Vac (AC-15), 4A at 220-240Vac (AC-15), 3A at 380-400Vac (AC-15), and 2A at 500Vac (AC-15). The rated insulation voltage is 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on the plate. The net dimensions are 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. It consumes 3.5VA for both inrush and holding (coil), operates with a control voltage of 220Vac-240Vac (230Vac) at 40Hz-450Hz, and has a rated operating voltage (Ue) of 690 V. The contactor has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts, a rated impulse voltage (Uimp) of 6 kV, and supports operating rates of 300 cycles/hour (AC-1), 600 cycles/hour (AC-3), 360 cycles/hour (AC-15), 600 cycles/hour (DC-1), 360 cycles/hour (DC-13), and 600 cycles/hour (DC-3).
ABB Control
Quick Quote
Items per page: