Filters
More in this category
Contactors
part#
description
manufacturer
CA7-9-120-R7
Sprecher + Schuh CA7-9-120-R7 - CA7 Enc. Contactor FVNR, 9 A, 110V 50Hz / 120V 60Hz AC, Type 3R, Hand-Off-Auto SS
Sprecher + Schuh
Quick Quote
BF09T2A46060
BF09T2A46060 Lovato - Four-pole contactor, IEC operating current Ith (AC1) = 25A, AC coil 60Hz, 460VAC, 2NO and 2NC
Lovato Electric
Quick Quote
CWM95N-00-30V56
WEG CWM95N-00-30V56 - CONTACTOR CWM95N-00-30V56, Contactors (CWM)
WEG
Quick Quote
AF30R-30-22-14
REV,3P,32.2A,250-500VAC/DC,2/2
ABB Control
Quick Quote
CWC09-10-30C12
WEG CWC09-10-30C12 - MINICONTACTOR CWC09-10-30C12, Miniature Contactors (CWC)
WEG
Quick Quote
BF18T0A024
BF18T0A024 Lovato - Four-pole contactor, IEC operating current Ith (AC1) = 32A, AC coil 50/60Hz, 24VAC, 4NC
Lovato Electric
Quick Quote
11B63010000060
11B63010000060 Lovato - Three-pole contactor, IEC operating current Ith (AC1) = 1000A, AC/DC coil, 60VAC/DC
Lovato Electric
Quick Quote
AF30R-30-02-11
REV,3P,32.2A,20-60VDC/24-60VAC,2NC
ABB Control
Quick Quote
BF0022A57560
BF0022A57560 Lovato - Control relay with AC coil 60Hz, 575VAC, 2NO and 2NC
Lovato Electric
Quick Quote
AF121F2-CE11V927
ABB Control - AF121F2-CE11V927
ABB Control
Quick Quote
BFS2523A230
BFS2523A230 Lovato - Three-pole safety contactor, IEC operating current Ie (AC3) = 25A, AC coil 50/60Hz, 230VAC, 2NO+3NC auxiliary contact
Lovato Electric
Quick Quote
GJH1213003R0401
ABB GJH1213003R0401 is a magnetic mini contactor from the KC6 contactors sub-range, designed with 4-poles (4NO) and flat pin / Faston connections. It supports a rated current of 4A at 24-240Vac (AC-15), 3A at 440Vac (AC-15), 2A at 500Vac (AC-15), and 5A at 600Vac (UL/CSA general use rating). The rated insulation voltage is 690 V (IEC/VDE) and 600 V (UL/CSA), with a mounting mode on the plate. Its dimensions are 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. The control voltage is 24Vdc, with a current consumption of 3.5W for both inrush and holding (coil). The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it can operate at a rate of 600 cycles/hour (DC-13).
ABB Control
Quick Quote
AF261B2-AD11Q9
AF26,NR,3PH,CB,N3R/4/12,200/120V
ABB Control
Quick Quote
11G326
11G326 Lovato - Paralleling links. Clamp-screw terminals, for BG... series mini-contactors, for 4 poles
Lovato Electric
Quick Quote
J7KC-12-10 AC220
J7KC-12-10 AC220, Magnetic Contactor, Max Load Current: 5-15A, Max Rated Load Voltage : 200-400 VAC, Input Voltage Range: 220-240 VAC
Omron
Quick Quote
J7KCA-31 AC110
J7KCA Auxiliary Contact Relay
Omron
Quick Quote
CA9-305-11-48W
Sprecher + Schuh CA9-305-11-48W - CA9 Contactor, 305A, 48-130V 50-60 Hz AC/DC, 1NO1NC
Sprecher + Schuh
Quick Quote
GJL1211201R8004
ABB GJL1211201R8004 is a magnetic mini contactor from the B6 contactors sub-range, featuring screw-clamp connections and a 4-pole (4NO) configuration. It supports rated currents of 20A at 380-400Vac (40°C; AC-1), 16A at 380-400Vac (55°C; AC-1), 6A at 690Vac (40°C; AC-1), 6A at 690Vac (55°C; AC-1), with AC-15 ratings of 4A at 24-120Vac, 4A at 220-240Vac, 3A at 380-400Vac, and 2A at 500Vac. Additionally, it has UL/CSA FLA ratings including 5.8A at 115Vac (single-phase) and 4.8A at 440-480Vac (3-phase). The contactor has a rated insulation voltage of 690 V (IEC/VDE) and 600 V (UL/CSA), with a control voltage of 110Vac-127Vac (40-450Hz). It is designed for mounting on a plate, with dimensions of 57.5 mm in height, 52.5 mm in width, and 46.5 mm in depth. The current consumption is 3.5VA for both inrush and holding (coil). The rated operating voltage (Ue) is 690 V, with no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it has rated active power outputs of 2.2kW at 220-240Vac (AC-3), 4kW at 380-440Vac (AC-3), 4kW at 500Vac (AC-3), and 3kW at 690Vac (AC-3). The rated power (HP) is 2HP at 220-240Vac (3-phase; UL/CSA), 3HP at 440-480Vac (3-phase; UL/CSA), and 1HP at 550-600Vac (3-phase; UL/CSA). The operating rates are 300 cycles/hour (AC-1), 600 cycles/hour (AC-3), 360 cycles/hour (AC-15), 600 cycles/hour (DC-1), 360 cycles/hour (DC-13), and 600 cycles/hour (DC-3).
ABB Control
Quick Quote
AF301B2-AV6A
AF30,NR,3PH,CB,N3R/4/12,200/120V
ABB Control
Quick Quote
LC1F3304F7
Schneider Electric LC1F3304F7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports ring-lugs/bar connections. This contactor is rated for a current of 400A (AC-1) and operates at a control voltage range of 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 1000 V, with a rated impulse voltage (Uimp) of 8 kV. It has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The mechanical durability of this contactor is rated at 10,000,000 operations at no load, and it is designed to handle a phase-to-phase rated voltage (AC) of 1000 V.
Schneider Electric
Quick Quote
Items per page: