Filters
More in this category
Contactors
part#
description
manufacturer
LC1DT80A3ED
Schneider Electric LC1DT80A3ED is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a robust installation. This 4-pole (4NO) contactor is designed to handle a rated current of 80A (AC-1) and can be mounted on a DIN rail. With a net width of 70 mm and an IP20 degree of protection, it is compact and offers basic protection against touch. The control voltage ranges from 36-60Vdc, with a nominal 48Vdc, allowing for flexible operation within 0.75 to 1.25 times the control voltage (Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC), enhancing its functionality. The contactor is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and offers a mechanical durability of 6 million operations at no load. It is rated for a phase-to-phase voltage of up to 690 V AC, making it suitable for a wide range of applications.
Schneider Electric
Quick Quote
LC1D65A3L7
Schneider Electric LC1D65A3L7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and operates with 3 poles (3P; 3NO). This contactor supports a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D65A3L7 offers an IP20 degree of protection and operates with a control voltage of 160-220Vac at 50Hz and 170-220Vac at 60Hz. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. Additionally, it features 1 normally closed (NC) auxiliary contact and instantaneous auxiliary contacts type of 1NO+1NC. The rated power in horsepower varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,400,000 operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
AF09N00ZR-3022-23
N.REV,SZ00,LOW100-250VAC/DC,2/2
ABB Control
Quick Quote
11BG0901D220
11BG0901D220 Lovato - Three-pole contactor, IEC operating current Ie (AC3) = 9A, DC coil, 220VDC, 1NC auxiliary contact
Lovato Electric
Quick Quote
J7KNA-09-4 230
Omron J7KNA-09-4 230 - Contr,9A,4main pole,240VAC
Omron
Quick Quote
AF301B2-GE27
ABB Control - AF301B2-GE27
ABB Control
Quick Quote
11BG0601D110
11BG0601D110 Lovato - Three-pole contactor, IEC operating current Ie (AC3) = 6A, DC coil, 110VDC, 1NC auxiliary contact
Lovato Electric
Quick Quote
CA9-146-11-120W
Sprecher + Schuh CA9-146-11-120W - CA9 Contactor, 146A, 100-250V 50-60 Hz AC/DC, 1NO1NC
Sprecher + Schuh
Quick Quote
BF0022A400
BF0022A400 Lovato - Control relay with AC coil 50/60Hz, 400VAC, 2NO and 2NC
Lovato Electric
Quick Quote
CAU7-9E-22-U24E
Sprecher + Schuh CAU7-9E-22-U24E - CAU7 Contactor FVR, 9A, 24V DC Elec. Coil, 2NO 2NC, Reversed Coil
Sprecher + Schuh
Quick Quote
BFK0910A048
BFK0910A048 Lovato - Contactor for power factor correction with AC control circuit, including limiting resistors, maximum IEC operational power 400V = 7.5kvar, coil 48VAC 50/60Hz
Lovato Electric
Quick Quote
CA7-30-00-600
Sprecher + Schuh CA7-30-00-600 - CA7 Contactor, 30A, 550V 50Hz / 600V 60Hz AC,
Sprecher + Schuh
Quick Quote
CAU8-09C-42-24DD-PW
Sprecher + Schuh CAU8-09C-42-24DD-PW - CAU8 Miniature Contactor FVR, 9A, 24V DC w/Diode, 4NO 2NC, Power Wiring
Sprecher + Schuh
Quick Quote
J7KN-176 230
Omron J7KN-176 230 - Contactor
Omron
Quick Quote
AF3011-BE29
ABB Control - AF3011-BE29
ABB Control
Quick Quote
LC1DT80A6U7
Schneider Electric LC1DT80A6U7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with ring-lugs connections and has a 4-pole (4P; 4NO) configuration. The contactor is rated for 80A under AC-1 conditions and is designed for DIN rail mounting. With a net width of 70 mm, it offers an IP20 degree of protection. The control voltage for AC ranges from 192-264Vac at 50Hz and 204-264Vac at 60Hz, with a nominal voltage of 240Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both of the instantaneous type. The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6 million operations at no load. The rated voltage for phase-to-phase applications is up to 690 V AC.
Schneider Electric
Quick Quote
CWB38-11-30C15
WEG CWB38-11-30C15 - CONTACTOR CWB38-11-30C15, Contactors (CWB)
WEG
Quick Quote
CA8-09-10-48Z
Sprecher + Schuh CA8-09-10-48Z - CA8 Miniature Contactor, 9A, 48V 50/60Hz AC, 1NO
Sprecher + Schuh
Quick Quote
LC1D65A6V7
Schneider Electric LC1D65A6V7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 65A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D65A6V7 offers an IP20 degree of protection and operates with a control voltage (AC) range of 320-440Vac at 50Hz and 340-440Vac at 60Hz, with a nominal voltage of 400Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power up to 37kW for various AC-3 voltage levels and offers rated power in horsepower for different configurations, reaching up to 50HP for 575-600Vac 3-phase applications according to UL/CSA standards. It boasts a mechanical durability of 6 million operations and an electrical durability of 1.4 million operations with load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric
Quick Quote
AF12N0-30-10-41
AF12N0-30-10-41 ABB Control - AF12N0-30-10-41 24-60V50/60HZ Contactor
ABB Control
Quick Quote
Items per page: