ACOPOSmulti SafeMOTION EnDat 2.2 inverter module, 44 A, AS, cold plate or pass-through mounting
Check out the 8BVI0440HCSS.000-1 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight4.3 kg
- Type EnDat 2.2
- Quantity 2
- Peak current 88 Aeff
- Max. output frequency 598 Hz
- Max. extinction energy per switching operation 3 Ws
- Output voltage 24 VDC +5.8% / -0.5%
- Overvoltage category per EN 61800-5-1 III
- Encoder monitoring Yes
- Certifications Functional safety Yes (openSAFETY)
- Output voltage DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
- Encoder power supply Load capacity 350 mA
- Permissible mounting orientations Horizontal, face up Yes
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Cold plate mounting 0.8 A/K (starting at 45°C)
- Encoder power supply Protective measures Short-circuit proof Yes
- Cooling and mounting type Cold plate or pass-through mounting
- Connections 9-pin female DSUB connector
- Modulation compared to ground potential Max. ±38 V
- Power dissipation depending on switching frequency Switching frequency 10 kHz [0.2 * IM² + 11.1 * IM + 130] W
- Installation elevation above sea level Maximum 4000 m
- Electrical isolation Input - Input Yes
- Protective measures Undervoltage monitoring Yes
- Dimensions Width 106.5 mm
- Dimensions Depth Cold plate 212 mm
- DC bus capacitance 990 µF
- Power dissipation depending on switching frequency Switching frequency 20 kHz [1.85 * IM² + 3.8 * IM + 300] W
- Max. motor line length depending on switching frequency Switching frequency 5 kHz 25 m
- Synchronous serial interface Data transfer rate 6.25 Mbit/s
- Installation elevation above sea level Nominal 0 to 500 m
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Cold plate mounting 0.62 A/K (starting at 6°C)
- Temperature Operation Maximum 55°C
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Cold plate mounting 0.32 A/K (starting at -82°C)
- Dimensions Depth Pass-through mounting 209 mm
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Pass-through mounting 0.24 A/K (starting at -137°C)
- Terminal connection cross section Flexible and fine-stranded wires With wire end sleeves 0.5 to 16 mm²
- Encoder power supply Protective measures Overload-proof Yes
- Terminal connection cross section Approbation data UL/C-UL-US 20 to 6
- Temperature Operation Nominal 5 to 40°C
- Terminal connection cross section Approbation data CSA 20 to 6
- Variant ACOPOSmulti backplane
- Nominal switching frequency 5 kHz
- Response threshold for open-circuit monitoring Approx. 0.5 A
- Degree of protection per EN 60529 IP20
- Variant U, V, W, PE Connector
- Input voltage Maximum 30 VDC
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Pass-through mounting 0.37 A/K (starting at -36°C)
- Max. power consumption 31 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake
- Possible switching frequencies 5 / 10 / 20 kHz
- Continuous current 4.2 A
- Certifications EAC Yes
- Max. motor line length depending on switching frequency Switching frequency 20 kHz 25 m
- Switching threshold High >15 V
- Electrical isolation Input - Inverter module Yes
- Dimensions Height 317 mm
- Fuse protection 250 mA (slow-blow) electronic, automatic reset
- Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
- Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
- Certifications CE Yes
- Protective measures Overload and short-circuit protection Yes
- Permissible mounting orientations Standing horizontally No
- Continuous power consumption 32.5 kW
- Response threshold for undervoltage monitoring 24 VDC -2% / -4%
- Certifications KC Yes
- Relative humidity Transport Max. 95% at 40°C
- Slots for plug-in modules 2
- Input capacitance 32.9 µF
- Max. power consumption per encoder interface PSMC[W] = 19 V * IEncoder[A]
- Module width 2
- Power dissipation depending on switching frequency Switching frequency 5 kHz [0.07 * IM² + 7.3 * IM + 40] W
- Variant Shield connection Yes
- Protective measures Open-circuit monitoring Yes
- Switching delay Rising edge 52 µs ±0.5 µs (digitally filtered)
- Temperature Transport -25 to 70°C
- Input voltage 25 VDC ±1.6%
- Continuous current per motor connection 44 Aeff
- Terminal cable cross section dimension of shield connection 23 to 35 mm
- Discharge capacitance 0.22 µF
- Reduction of continuous current depending on installation elevation Starting at 500 m above sea level 4.4 Aeff per 1000 m
- Encoder power supply Output voltage Typ. 12.5 V
- Synchronous serial interface Signal transmission RS485
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Pass-through mounting 1.26 A/K (starting at 40°C)
- B&R ID code 0xAA1F
- Continuous power per motor connection 32 kW
- Extinction potential Approx. 30 V
- Status indicators UP/DN LEDs
- Circuit Sink
- Output voltage DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
- Protective measures Overload protection Yes
- Protective measures Short-circuit and ground fault protection Yes
- Input voltage Nominal 24 VDC
- Switching threshold Low <5 V
- Relative humidity Operation 5 to 85%
- Max. switching frequency 0.5 Hz
- Input current at nominal voltage Approx. 10 mA
- Voltage Nominal 750 VDC
- Relative humidity Storage 5 to 95%
- Max. internal resistance 0.15 Ω
- Max. motor line length depending on switching frequency Switching frequency 10 kHz 25 m
- Switching delay Falling edge 53 µs ±0.5 µs (digitally filtered)
- Permissible mounting orientations Hanging vertically Yes
- Max. encoder cable length 100 m ; Depends on the cross section of the power supply wires in the encoder cable
- Certifications UL cULus E225616; Power conversion equipment
- Electrical isolation Encoder - ACOPOSmulti No
- Temperature Storage -25 to 55°C
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 8BVI0440HCSS.000-1 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨